Armada - Process and Capacity 

Process

Entry specification Produced fluids must be commercially free of odours, materials, sand and solids/fluids that might interfere or cause injury to the proper operation of the Armada facility; which for the avoidance of doubt shall include any material that would affect the merchantable value of Armada products.
Exit specification To meet the required specifications of the Central Area Transmission System and the Forties Pipeline System.
Primary separation The Armada platform has a single processing train with initial low pressure separation.
Gas treatment A single stage processing process comprising separation, booster compression, dehydration, export compression and metering.
Oil export capacity 30,000 - 34,000 bbl/d
Gas comp capacity 10.76 mmscmd (at maximum suction pressure)
Gas export capacity Governed by compression
Gas lift capacity None
Produced water handling 11,050 bbl/d accessible
Dehydration capacity Governed by compression
H2S removal capacity None
Water injection capacity None

Notes

Infrastructure Code of Practice - published information ref Annex E

For more information on exit specification:

Please click here for the CATS website
(opens in a new window)

Please click here for the Forties Pipeline System website
(opens in a new window)


Capacity